Part Number Hot Search : 
CLL4750A CMN697 UFT12260 E306V0 AD9058KD 10021971 ADG918 PR6006
Product Description
Full Text Search
 

To Download STR1-SASU0AC8 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  online data sheet STR1-SASU0AC8 str1 non-contact safety switches
a b c d e f h i j k l m n o p q r s t STR1-SASU0AC8 | str1 non-contact safety switches ordering information type part no. STR1-SASU0AC8 1072710 other models and accessories www.sick.com/str1 detailed technical data features system part sensor and actuator sensor principle transponder number of safe outputs 2 auxiliary contact (aux) 1 safe switch on distance s ao active front sensor surface 10?mm active side sensor surface 6?mm safe switch off distance s ar 25?mm active sensor surfaces 3 actuation directions 5 coding uniquely coded safety-related parameters safety integrity level sil3 (iec?61508), silcl3 (en?62061) category category 4?(en?iso?13849) performance level pl?e?(en?iso?13849) pfh d (mean probability of a dangerous fail- ure per hour) 5,21?x?10 -9 (en?iso?13849) t m (mission time) 20?years (en?iso?13849) type type 4?(en?iso?14119) actuator coding level high coding level (en?iso?14119) safe state in the event of a fault at least one safety-related semiconductor output (ossd) is in the off state. functions cascading ? interfaces connection type cable with plug m12, 8-pin length of cable 0.2?m cable material pvc diagnostics indicator ? 2 safety switches | sick online data sheet | 2018-09-06 10:37:18 subject to change without notice
STR1-SASU0AC8 | str1 non-contact safety switches status display ? electrical data protection class iii (iec?61140) classification according to culus class 2 supply voltage v s 24?v?dc (19.2?v?dc?... 28.8?v?dc) power consumption 50?ma type of output semiconductor (ossd) output current ?100?ma response time 40?ms? 1) enable time 100?ms? 1) ? 2) risk time 80?ms? 1) ? 3) switch-on time 2.5?s? 4) 1) ?in a cascade, each downstream safety switch increases the system response time . more response times can be found in the operating instructions. 2) ?response time on approach to the enable zone. 3) ?detection time for internal oder external faults (e.g., short-circuit or cross-circ uit of output signal switching devices). follow the detailed information in the operating instructions. 4) ?the stated time applies for one sensor after application of the supply voltage to the safety switch. in case of a cascade 0.1?s must be added per sensor. for uniquely coded or permanently coded sensors 0.5?s must be added additionally per taught-in ac tuator. mechanical data dimensions (w?x h?x d) 40?mm?x 18?mm?x 26?mm weight 82?g housing material vistal? ambient data enclosure rating ip67 (en?60529) ipx9k (iso?20653) ambient operating temperature C10?c?... +70?c storage temperature C25?c?... +70?c vibration resistance 10?hz?... 55?hz, 1?mm (iec?60068-2-6) shock resistance 30?g, 11?ms (iec?60068-2-27) emc en?iec?61326-3-1 en?iec?60947-5-2 en?iec?60947-5-3 en?300330 v2.1.1 classifications ecl@ss 5.0 27272403 ecl@ss 5.1.4 27272403 ecl@ss 6.0 27272403 ecl@ss 6.2 27272403 ecl@ss 7.0 27272403 ecl@ss 8.0 27272403 ecl@ss 8.1 27272403 ecl@ss 9.0 27272403 etim 5.0 ec001829 2018-09-06 10:37:18 | online data sheet subject to change without notice safety switches | sick 3
a b c d e f h i j k l m n o p q r s t STR1-SASU0AC8 | str1 non-contact safety switches etim 6.0 ec001829 unspsc 16.0901 39122205 dimensional drawing (dimensions in mm (inch)) sensor with cable and male connector 18 (0.71) 14 (0.55) m12 x 1 13.5 (0.53) ? 5.5 (? 0.22) 19 (0.75) 26.2 (1.03) 40 (1.57) 25 (0.99) 175 (6.89) 3 (0.12) 5 (0.2) ? 8.5 (? 0.33) 22 (0.87) "standard" actuator 18 (0.71) ? 4.5 (? 0.18) 19 (0.75) 22 (0.87) 26.2 (1.03) 5 (0.2) ? 8.5 (? 0.33) 40 (1.57) 4 safety switches | sick online data sheet | 2018-09-06 10:37:18 subject to change without notice
STR1-SASU0AC8 | str1 non-contact safety switches response range "standard" actuator, active side sensor surface 40 (1.57) 20 (0.79) 20 (0.79) 40 (1.57) 0 0 4 (0.16) 8 (0.31) 12 (0.47) 16 (0.63) 20 (0.79) [mm] (inch) safe switch on distance s ao 6?mm "standard" actuator, active front sensor surface 40 (1.57) 20 (0.79) 20 (0.79) 40 (1.57) 0 0 4 (0.16) 8 (0.31) 12 (0.47) 16 (0.63) 20 (0.79) [mm] (inch) safe switch on distance s ao 10?mm. pay attention to boundary areas in case of parallel approach: if the actuator m oves laterally in relation to the surface of the sensor, a minimum distance of 6?mm must be main tained. this distance will prevent premature trig- gering due to the side approach areas. 2018-09-06 10:37:18 | online data sheet subject to change without notice safety switches | sick 5
a b c d e f h i j k l m n o p q r s t STR1-SASU0AC8 | str1 non-contact safety switches connection diagram 12 3 4 5 6 7 8 aux output (not safe) voltage supply 24 v dc not connected enable input for ossd 2 ossd 1 ossd 2 voltage supply 0 v dc enable input for ossd 1 2 1 6 4 85 3 7 connection single sensor 2 3 1 ??safe evaluation unit ??connecting cable with 8-pin, m12 female connector and flying leads (e.g., yf2a18-xxxua5leax) ??str1 transponder safety switch (e.g., str1-saxx0ac8) 6 safety switches | sick online data sheet | 2018-09-06 10:37:18 subject to change without notice
STR1-SASU0AC8 | str1 non-contact safety switches series connection series connection with t-piece (without diagnostics) 2 1 3 3 3 4 4 5 7 6 7 6 7 6 ??safe evaluation unit ??connecting cable with 4-pin, m12 female connector and flying leads (e.g., yf2a14-xxxvb3xleax) ??tr4-ak004c t-connector ??connection cable with 4-pin, m12 male connector and 4-pin, m12 female connector (e.g., yf2a14-xxxv b3m2a14) ??mlp1-xxt end connector ??connection cable with 8-pin, m12 male connector and 8-pin, m12 female connector (e.g., yf2a18-xxxu a5m2a18) ??str1 transponder safety switch (e.g., str1-saxx0ac8) 2018-09-06 10:37:18 | online data sheet subject to change without notice safety switches | sick 7
a b c d e f h i j k l m n o p q r s t STR1-SASU0AC8 | str1 non-contact safety switches series connection of three str1 transponder safety switches to a flexi classic safe ty controller ue410-mu/xu +24 v dc 8 function q1 i4 i3 a2 en q3 q2 q4 a1 i2 i1 x1 x2 s1 s2 s3 fe k1 k2 k1 reset k2 0 v fe e148462/00/2016-02-08 str1 2 4 3 8 7 6 1 5 str1 2 4 3 8 7 6 1 5 str1 2 4 3 8 7 6 1 5 recommended accessories other models and accessories www.sick.com/str1 brief description type part no. nuts and screws 10?pieces safety screws m4?x 20 5333571 plug connectors and cables head a: female connector, m12, 8-pin, straight, a-coded head b: flying leads cable: sensor/actuator cable, pur, halogen-free, unshielded, 2?m yf2a18-020ua5xleax 2095652 head a: female connector, m12, 8-pin, straight, a-coded head b: flying leads cable: sensor/actuator cable, pur, halogen-free, unshielded, 5?m yf2a18-050ua5xleax 2095653 head a: female connector, m12, 8-pin, straight, a-coded head b: flying leads cable: sensor/actuator cable, pur, halogen-free, unshielded, 10?m yf2a18-100ua5xleax 2095654 8 safety switches | sick online data sheet | 2018-09-06 10:37:18 subject to change without notice
online data sheet sick ag | waldkirch | germany | www.sick.com sick at a glance sick is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applica- tions. a unique range of products and services creates the perfect basis for controlling processes securely and eficiently, protecting individuals from accidents and preventing damage to the environment. we have extensive experience in a wide range of industries and understand their processes and require- ments. with intelligent sensors, we can deliver exactly what our customers need. in application cent ers in europe, asia and north america, system solutions are tested and optimized in accordance with custome r speciications. all this makes us a reliable supplier and development partner. comprehensive services complete our offering: sick lifetime services provide support throughout the ma- chine life cycle and ensure safety and productivity. for us, that is sensor intelligence. worldwide presence: contacts and other locations www.sick.com


▲Up To Search▲   

 
Price & Availability of STR1-SASU0AC8

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X